Fire curves in tunnel fire protection
Fire curves describe how temperature develops over time in a tunnel fire and form the basis for designing fire protection systems. Requirements differ by tunnel type, country and risk scenario – from the ISO standard curve to the RWS and HCM curves. Aestuver® fire protection boards meet or exceed the requirements of these internationally recognised curves.
Why are fire curves so important in tunnel construction?
Tunnel fires reach extreme temperatures very quickly – the EBA curve, for example, assumes 1,200 °C after just five minutes. Loads like these threaten the load-bearing capacity of concrete and reinforcement and can cause concrete spalling. Tunnel structures are therefore designed using standardised time-temperature curves that replicate real fire scenarios as closely as possible.
What is a fire curve?
A fire curve (time-temperature curve) describes how the temperature develops over time during a fire. It forms the basis for tunnel design requirements – such as the thickness of the fire protection cladding and the escape and rescue strategy.
Fire curves are used to verify that:
the load-bearing capacity is maintained
the concrete surface and reinforcing steel stay below their critical temperatures
concrete spalling is prevented
the tunnel can be repaired after a fire
Which fire curves apply to tunnels?
Six fire curves. One goal.
The curves differ in how the fire develops, how quickly the maximum temperature is reached and how long it lasts – but they all share the same aim: to protect people, infrastructure and structures in a fire.
What happens to a tunnel at these temperatures?
The consequences go far beyond the fire damage
Spalling can compromise the integrity of the tunnel structure and reduce the load-bearing capacity of critical structural elements.
Once the concrete cover spalls, the reinforcement is left unprotected – exposed to high temperatures and, through hairline cracks, to carbonation and chlorides that can corrode the steel.
Repairing fire-damaged concrete is complex and leads to substantial repair and restoration costs.
Severe fire damage can close a tunnel for long periods – with a significant impact on traffic, tunnel operators and the surrounding region.
Aestuver® fire protection boards
Aestuver® fire protection boards meet or exceed the requirements of internationally recognised tunnel fire curves – ISO, ZTV-ING, EBA, HC, HCM and RWS. They form a thermal barrier between the fire and the load-bearing structure, reducing concrete spalling and damage to the reinforcement.
Tested to international tunnel fire curves
Fire protection up to 1,350 °C (board T) or 1,400 °C (board Tx)
Reduces concrete spalling
For new builds and refurbishments
Cast into the concrete or post-fixed
White paper: How cost-effective is fire protection in tunnels?
The costs of a tunnel fire are often driven not by the fire itself, but by consequential damage, restoration work and long closures.
Talk to our tunnel experts
Have a specific requirement? Our tunnel fire protection specialists will work with you to develop the right solution – from planning support and project-specific fire tests to technical assistance on site.
FAQ
Concise answers to the key questions about tunnel fire curves and the use of Aestuver® fire protection boards in tunnels.
The appropriate fire curve depends on the type of tunnel, the statutory requirements, the volume of traffic and the project’s risk profile. Whilst, for example, road tunnels are frequently designed in accordance with RWS or HC fire curves, different requirements often apply to railway tunnels. Aestuver® supports planners and engineers in selecting the appropriate fire protection system for the required fire resistance. |
No. The panels are made of cement-bound, glass-fibre-reinforced lightweight concrete and are classified as a Class A1 non-combustible building material. |
Different fire curves are used depending on the country, application and project requirements. The most important of these include the ISO, ZTV-ING, EBA, HC, HCM and RWS curves. They represent different fire scenarios and temperature profiles. |
Aestuver® systems have been tested against international tunnel fire performance curves, including RWS, HCM, HC, EBA, ZTV-ING/RABT and ISO 834. |
Depending on the product and system requirements, these solutions offer protection at temperatures of up to 1,350 °C, or in the case of Aestuver® Tx, even up to 1,400 °C. |
More Aestuver® products