Frequently asked questions about tunnel fire protection
Answers to the most common questions about concrete spalling, tunnel fire protection and the applications of Aestuver® fire protection boards.
Concrete spalling can compromise the load-bearing capacity of the structure, expose the reinforcement and necessitate extensive repair work. It can also result in long periods of closure and high follow-on costs. |
Existing tunnels can be protected by retrofitting fire protection cladding. The fire protection panels are mechanically fixed to walls and ceilings, protecting the existing concrete structure from damaging temperatures in the event of a fire. |
Different fire curves are used depending on the country, application and project requirements. The most important of these include the ISO, ZTV-ING, EBA, HC, HCM and RWS curves. They represent different fire scenarios and temperature profiles. |
Passive fire protection acts as a thermal barrier between the fire and the concrete structure. This reduces the critical temperatures reached by the concrete and reinforcement, thereby significantly reducing the risk of concrete spalling. |
Depending on the fire scenario, temperatures in tunnels can exceed 1,200 °C. Some international tunnel fire curves even simulate temperature peaks of up to 1,350 °C. |
The cost of tunnel fire protection depends on factors such as tunnel geometry, duration of protection, fire curve and the chosen system. However, the investment can pay for itself simply by preventing serious damage to the concrete, reducing closure times and minimising repair costs following a fire. The aim is to provide long-term protection for the tunnel structure and to ensure the long-term availability of the structure. |
The appropriate fire curve depends on the type of tunnel, the statutory requirements, the volume of traffic and the project’s risk profile. Whilst, for example, road tunnels are frequently designed in accordance with RWS or HC fire curves, different requirements often apply to railway tunnels. Aestuver® supports planners and engineers in selecting the appropriate fire protection system for the required fire resistance. |
The requirements for structural fire protection in road tunnels are based on the relevant national regulations and the structure’s safety concept. Tunnel fire curves such as RWS, HC or ZTV-ING/RABT are frequently used to ensure the protection of the supporting structure in the event of a fire. Aestuver® tunnel fire protection systems are tested against various international tunnel fire curves and can be designed to meet specific project requirements. |
Yes. Studies show that fire protection panels can significantly reduce repair times and tunnel closures. This helps to reduce the high costs associated with diversions, traffic disruption and loss of use. |
Individual slabs can be removed for inspections or repairs and then reinstalled. This ensures that leaks or damage to the concrete structure remain easily accessible. |
Yes. The surface is abrasion-resistant and can be cleaned using high-pressure washers, tunnel wash systems or industrial brushes. Its cleanability has been tested in accordance with DIN EN ISO 11998. |
Depending on the product and system requirements, these solutions offer protection at temperatures of up to 1,350 °C, or in the case of Aestuver® Tx, even up to 1,400 °C. |
The systems can be used in both road and railway tunnels. They are also suitable for underground railway systems, escape routes, cable ducts, smoke extraction systems and technical infrastructure in tunnel structures. |
Explore Aestuver® tunnel solutions
Get a structured overview of Aestuver® tunnel solutions – products, solutions and fire protection systems for a wide range of tunnel and infrastructure requirements.