Frequently asked questions about Aestuver® FireShield
Answers to the most important questions about planning, applying and using Aestuver® FireShield.
Yes, Aestuver® FireShield is also suitable for timber construction. The elements are usually delivered directly to the manufacturer of the timber ceiling elements, who installs the Aestuver® FireShield fire stop in the timber elements at the factory. This ensures reliable fire protection and fall protection in every phase of construction.
As the side wall of Aestuver® FireShield is made from a 25 mm fire protection board, additional lining of the opening is not needed in most cases. The elements are made to exact dimensions according to the opening plan; they are simply inserted into the opening and fixed at the sides in the reveal with screw anchors.
Special situations:
Cast timber-hybrid floor: Aestuver® FireShield is fixed to the formwork in the usual way and cast into the concrete – no additional mechanical fixing with screw anchors is required.
Timber-hybrid floor with concrete elements: Aestuver® FireShield is mechanically fixed to the sides of the timber structure; the concrete elements are joined to the sides of the element.
Timber floor: Aestuver® FireShield is delivered directly to the element manufacturer and installed there, or placed in the opening on site and mechanically fixed at the sides.
Yes, Aestuver® FireShield can be fitted into an existing opening. An Aestuver® FireShield partner company measures the opening on site; the element is then made to these exact dimensions, inserted into the existing opening and fixed at the sides with screw anchors.
No, there is no loss of space. The side wall of Aestuver® FireShield is 25 mm thick, and the space available between the reinforcement and the opening is 30 mm, so the element can be integrated without taking up extra space and the clear opening dimensions are retained.
The only exception is next to seismic walls: as the side wall of Aestuver® FireShield must not be cast into the load-bearing wall, the element is supplied with screw anchors, which are then cast into the wall.
No, specific design adjustments are not usually necessary. The spacing between services can be kept as with a conventional fire stop. However, given the low minimum clearances that have been verified, it may be worth revising the layout if you want to save space and use smaller shaft cross-sections.
The elements are usually ordered directly by the main contractor. Aestuver® always provides tender texts and specification extracts free of charge.
Yes – with many benefits. Since the latest approvals were introduced, Aestuver® FireShield elements have increasingly been used in residential construction too. As well as removing the need for various fire protection components – such as special fire-resistant insulation or fire protection collars at penetrations – Aestuver® FireShield ensures continuous watertightness. This means building services installation can start before the shell construction of the upper floors is complete.
Aestuver® FireShield is also ideal for smaller openings, for example for individual service lines. The openings are made easily by an Aestuver® FireShield partner company and replace costly core drilling.
The largest standard element measures 2,600 × 1,250 mm. On request, custom sizes of up to 12,500 × 1,250 mm or 4,000 × 2,600 mm can be produced – Aestuver® FireShield is made to measure for each project.
Using Aestuver® FireShield elements for openings in riser zones offers economic and practical advantages and speeds up building services installation. Because Aestuver® FireShield combines formwork, fire stop, fall protection and waterproofing in a single solution, lower storeys can already be fitted out while upper storeys are still at the shell construction stage. EI90 fire protection and fall protection with an approved surface load of 800 kg/m² are ensured throughout the construction phase, and once cast into concrete, Aestuver® FireShield is permanently watertight.
In addition, the tested minimum clearances between pipes – down to zero – allow more compact shaft planning, and the space saved brings clear financial benefits.
The Aestuver® FireShield elements are installed under the responsibility of the site foreman. As the foreman is in direct contact with the Aestuver® FireShield partner company, delivery dates and batch sizes are agreed jointly. The foreman then receives a numbered opening plan from the partner company, which clearly shows every element and its position.
Thanks to new penetration tests on Aestuver® FireShield, special fire-resistant rubber insulation is no longer needed, so services with continuous insulation can be routed directly through Aestuver® FireShield. Other fire protection components, such as fire protection collars for thermoplastic pipes up to 110 mm in diameter, are also no longer required. The Aestuver® FireShield cover plate provides fire protection to S90/EI90.
The elements are usually configured and manufactured according to the project’s opening plan. In addition to project-specific prefabrication, the following standard sizes are available: 625 × 625 mm, 1,250 × 625 mm and 1,250 × 2,600 mm. On request, we are also happy to develop a standard size with you for your typical construction method.
Aestuver® FireShield elements are manufactured at our factory in Calbe (Saale), Germany, in accordance with the requirements of the aBG. The fire protection boards used for them are also produced there.
Both the openings in Aestuver® FireShield and the fire stops for these openings are made by a trained specialist company – giving you a clean, complete solution from a single source. As safety is our top priority, our partner companies attend refresher training every year so that they are always aware of the specific risks of working in riser zones.
In principle, the site management decides when the openings in Aestuver® FireShield are made. However, the Aestuver® FireShield team recommends that the Aestuver® FireShield partner company only cuts the openings once the floor above has been concreted with its Aestuver® FireShield elements. This keeps the building watertight and allows building services installation to start promptly.
Find out more about Aestuver® FireShield
A clearly structured overview of Aestuver® FireShield as a complete system – with detailed information on planning, application and installation throughout the construction process.