Changes in temperature, settlement and loads cause movement within tunnel structures. Aestuver® fire protection solutions for expansion and movement joints provide the necessary flexibility whilst ensuring that the structure’s fire resistance is maintained.
Safe joint solutions for tunnels and infrastructure structures
Expansion and movement joints are essential components of modern tunnels and civil engineering structures. They accommodate movements caused by temperature changes, settlement or other structural influences. At the same time, these joints must not constitute a weak point in the event of a fire.
Aestuver® offers high-performance fire protection solutions for expansion and movement joints that permanently accommodate movement whilst meeting structural fire safety requirements. This ensures that tunnel structures remain protected even under extreme conditions. These solutions are based on the systems for expansion and movement joints described in the tunnel brochure.
Expansion joints prevent internal stresses from damaging the structure. To ensure that the structure continues to function properly, the joints must remain flexible whilst also being protected against fire and hot combustion gases.
A suitable fire safety solution ensures that:
Expansion joints allow for the controlled absorption of deformations within the structure and contribute to the long-term functionality of the building.
There must be no fire safety weaknesses in the area of expansion joints either. Suitable systems help to maintain the fire resistance of the adjacent structural elements.
High temperatures can damage sensitive waterproofing systems. Fire protection solutions safeguard the underlying structural elements and help to ensure the tunnel structure remains functional.
The combination of movement compensation and fire protection ensures that the structure’s safety, durability and usability are maintained even under demanding conditions.
Solutions for a range of requirements
Different systems are used depending on the structure’s geometry, movement absorption and fire safety requirements. Aestuver® offers solutions for various joint widths and ranges of movement that ensure fire safety whilst maintaining the necessary flexibility of the structure.
Flexible fire protection for a variety of installation scenarios
Expansion joint with Aestuver® joint cord T
Expansion joint with sliding cover – detail
Expansion joint with a sliding cover
Expansion joint with joint sealant
Aestuver™ FPM mastic
Aestuver® Expansion Joint B
Aestuver® Expansion Joint M
Aestuver® Tunnel Brochure
De Aestuver® Fire Protection Planner-software vereenvoudigt en versnelt het ontwerp van brandwerende bekledingen voor stalen constructies aanzienlijk. Civiel ingenieurs, ontwerpers van brandbeveiligingssystemen, projectontwikkelaars en aannemers profiteren niet alleen van op maat gemaakte brandbeveiligingsoplossingen, maar ook van informatie over het ontwerp en de installatie. Bovendien worden de specifieke materiaalbehoeften direct berekend. De applicatie is uiterst gebruiksvriendelijk.
Project consultancy from our tunnel experts
Do you need help planning fire protection for joints?
Every tunnel and infrastructure project has its own specific requirements in terms of movement absorption, fire resistance and component protection. Our experts can assist you in selecting and designing the appropriate fire protection solution for expansion and movement joints.
FAQ
Here you will find concise answers to the most important questions regarding the use of our fire protection panels in tunnels.
The requirements for structural fire protection in road tunnels are based on the relevant national regulations and the structure’s safety concept. Tunnel fire curves such as RWS, HC or ZTV-ING/RABT are frequently used to ensure the protection of the supporting structure in the event of a fire. Aestuver® tunnel fire protection systems are tested against various international tunnel fire curves and can be designed to meet specific project requirements. |
Yes. Aestuver® Tx has been specially developed for retrofitting and modernising existing tunnels and can be fixed directly to walls and ceilings. |
The systems can be used in both road and railway tunnels. They are also suitable for underground railway systems, escape routes, cable ducts, smoke extraction systems and technical infrastructure in tunnel structures. |
Aestuver® T is cast directly into the concrete and is particularly suitable for new construction projects. Aestuver® Tx is mechanically fixed and is suitable for both new construction projects and retrofitting and refurbishment work on existing tunnels. |
Yes. The panels are classified as Type X, the highest exposure class, and are permanently resistant to water, frost and weathering. This makes them ideal for the damp conditions found in tunnels. |
Other products
Discover the wide range of applications for Aestuver® fire protection boards here. These range from structural fire protection applications and demanding infrastructure projects to solutions for tunnel construction and other specialist applications.