Passive fire protection for road and rail tunnels

Tunnel fires can reach 1,200 °C within minutes. Aestuver® passive fire protection boards shield the concrete and reinforcement from this heat – preventing explosive spalling, preserving load-bearing capacity and keeping closures after a fire to a minimum.

Why do tunnels need passive fire protection?

Confined space, extreme heat, high stakes

In the confined space of a tunnel, temperatures rise within minutes and escape, rescue and repair become far more difficult. Without passive fire protection, the structure can suffer severe damage – resulting in long closures, extensive refurbishment and significant economic losses for operators and the surrounding region.

Protects the tunnel structure

Aestuver® boards shield the tunnel lining from extreme temperatures and prevent damage that could compromise structural stability and the safety of tunnel users.

Lower repair costs

Less structural damage means less restoration work and lower repair costs after a fire.

Faster return to service

Consequential damage is kept to a minimum and damaged boards can be replaced quickly, so the tunnel can be repaired and reopened to traffic sooner.

Long-term structural integrity

Load-bearing capacity and leak-tightness are maintained, safeguarding the long-term safety and availability of the infrastructure.

Concrete spalling: the greatest structural risk in a tunnel fire

Concrete spalling

What happens to concrete in a tunnel fire?
As concrete heats up, the moisture inside it evaporates and builds up steam pressure. This pressure can cause explosive spalling: layers of concrete break away, exposing the reinforcement and reducing the load-bearing capacity of the structure. High-strength and high-performance concretes are particularly susceptible, as their low porosity traps the steam.

Consequences of concrete spalling

  • Exposed reinforcement

  • Accelerated corrosion of the reinforcing steel

  • Loss of load-bearing capacity

  • Extensive refurbishment and long closures

How to prevent concrete spalling
Concrete spalling caused by fire exposure
How does passive fire protection work in tunnels?

A thermal barrier between the fire and the structure

Installed as permanent formwork or fixed to the finished lining, fire protection boards limit the temperature at the concrete surface and the reinforcing steel. The required performance is defined nationally or for each project using internationally recognised time-temperature curves: ISO 834, ZTV-ING (RABT), EBA, HC, HCM and RWS. Aestuver® boards meet or exceed the requirements of all of them.

Protects concrete and reinforcement

Limits the thermal load on the tunnel structure and protects load-bearing elements in the event of a fire.

Prevents concrete spalling

Keeps the concrete below critical temperatures, preventing explosive spalling and preserving structural integrity.

Preserves load-bearing capacity

Keeps concrete and reinforcement within the temperature limits set for the project – the precondition for structural stability in a fire.

Minimises consequential damage

Reduces restoration costs, downtime and the financial impact of a fire.

The biggest costs of a tunnel fire come afterwards

The greatest economic damage is rarely caused by the fire itself. Restoration work, long closures, diversions and lost revenue can multiply the cost of a single incident. A cost-effectiveness study by STUVA shows that the follow-up costs of a tunnel fire can far exceed the life-cycle costs of a passive fire protection system.

4×
higher loss of revenue

from tunnel closure than the life-cycle costs of the fire protection system*

6×
higher diversion costs

from detours and additional distance travelled during the closure*

15–20×
higher total losses

than the life-cycle costs of the fire protection boards*

*Example calculation for a toll tunnel with one major fire in 100 years (STUVA study, 2019)

White paper: the true cost of a tunnel fire

Find out what a tunnel fire really costs operators and the wider transport network – and why investing in passive fire protection pays off.

Why choose Aestuver® fire protection boards?

Long-term tunnel safety with Aestuver®

Aestuver® fire protection boards are made from cement-bonded, glass-fibre-reinforced lightweight concrete. They shield tunnel structures from extreme thermal loads and keep the structure intact in a fire. Non-combustible (A1), water- and frost-resistant and classified Type X for exposed applications, they meet the most demanding tunnel fire protection requirements – and leave room for individual design, from coatings to ceramic tile finishes.

Explore Aestuver® fire protection boards

Aestuver® fire protection boards at a glance

Non-combustible, heat-resistant, water- and frost-resistant: Aestuver® fire protection boards reliably protect tunnel structures from the consequences of a fire.

Non-combustible
Class A1 to EN 13501-1

The boards add no fire load and release no combustible components in a fire – meeting the strictest structural fire protection requirements for tunnels.

up to 1,400 °C
fire protection rating

Fire protection up to 1,350 °C (board T) or 1,400 °C (board Tx), tested to international tunnel fire curves.

Weather-resistant
Type X to EAD 350142-00-1106

Resistant to water and freeze–thaw cycles, Aestuver® boards provide durable fire protection in areas fully or partially exposed to the weather.

Easy to maintain
cleanability verified to DIN EN ISO 11998

Abrasion- and moisture-resistant with no organic components, so there is no risk of mould. Clean with high-pressure water jets or tunnel-cleaning vehicles.

Videos: tunnel fire protection in practice

Watch how Aestuver® fire protection systems protect tunnel structures and help keep closures to a minimum.

Talk to our tunnel experts

Have a specific requirement? Our tunnel fire protection specialists will work with you to develop the right solution – from planning support and project-specific fire tests to technical assistance on site.

FAQ

Answers to the most common questions about concrete spalling, tunnel fire protection and the applications of Aestuver® fire protection boards.

View all FAQs