Fire curves in tunnel fire protection

Fire curves describe how temperature develops over time in a tunnel fire and form the basis for designing fire protection systems. Requirements differ by tunnel type, country and risk scenario – from the ISO standard curve to the RWS and HCM curves. Aestuver® fire protection boards meet or exceed the requirements of these internationally recognised curves.

Why are fire curves so important in tunnel construction?

Tunnel fires reach extreme temperatures very quickly – the EBA curve, for example, assumes 1,200 °C after just five minutes. Loads like these threaten the load-bearing capacity of concrete and reinforcement and can cause concrete spalling. Tunnel structures are therefore designed using standardised time-temperature curves that replicate real fire scenarios as closely as possible.

What is a fire curve?

A fire curve (time-temperature curve) describes how the temperature develops over time during a fire. It forms the basis for tunnel design requirements – such as the thickness of the fire protection cladding and the escape and rescue strategy.

Fire curves are used to verify that:

  • the load-bearing capacity is maintained

  • the concrete surface and reinforcing steel stay below their critical temperatures

  • concrete spalling is prevented

  • the tunnel can be repaired after a fire

Internationally recognised time-temperature curves

What happens to a tunnel at these temperatures?

The consequences go far beyond the fire damage

01
Loss of load-bearing capacity

Spalling can compromise the integrity of the tunnel structure and reduce the load-bearing capacity of critical structural elements.

02
Exposed reinforcement

Once the concrete cover spalls, the reinforcement is left unprotected – exposed to high temperatures and, through hairline cracks, to carbonation and chlorides that can corrode the steel.

03
High refurbishment costs

Repairing fire-damaged concrete is complex and leads to substantial repair and restoration costs.

04
Long closure periods

Severe fire damage can close a tunnel for long periods – with a significant impact on traffic, tunnel operators and the surrounding region.

Aestuver® fire protection boards

Aestuver® fire protection boards meet or exceed the requirements of internationally recognised tunnel fire curves – ISO, ZTV-ING, EBA, HC, HCM and RWS. They form a thermal barrier between the fire and the load-bearing structure, reducing concrete spalling and damage to the reinforcement.

  • Tested to international tunnel fire curves

  • Fire protection up to 1,350 °C (board T) or 1,400 °C (board Tx)

  • Reduces concrete spalling

  • For new builds and refurbishments

  • Cast into the concrete or post-fixed

White paper: How cost-effective is fire protection in tunnels?

The costs of a tunnel fire are often driven not by the fire itself, but by consequential damage, restoration work and long closures.

Talk to our tunnel experts

Have a specific requirement? Our tunnel fire protection specialists will work with you to develop the right solution – from planning support and project-specific fire tests to technical assistance on site.

FAQ

Concise answers to the key questions about tunnel fire curves and the use of Aestuver® fire protection boards in tunnels.

View all FAQs