Fire protection boards for tunnels and infrastructure
Aestuver® offers four products developed specifically for tunnel and infrastructure construction: the Aestuver® fire protection board, board T, board Tx and the D+2 element. The non-combustible, glass-fibre-reinforced lightweight concrete boards are Class A1 with Type X classification and combine weather and moisture resistance with reliable structural fire protection.
Board T is cast directly into the concrete as permanent formwork; board Tx is fixed to the finished lining in new and existing tunnels. Both are fire-tested to the international tunnel fire curves RWS, HCM, ZTV-ING, EBA and ISO.
Aestuver® fire protection board
Aestuver® fire protection board T
Aestuver® fire protection board Tx
Aestuver® D+2 fire protection element
Built for every environment: Aestuver® fire protection boards
Reliable in any environment
Aestuver® fire protection boards made from glass-fibre-reinforced lightweight concrete are weather-resistant (Type X) and tested to the ÖBV guideline for areas fully or partially exposed to the weather. They withstand water and freeze–thaw cycles. In road tunnels, a surface coating is required for frost and de-icing salt resistance.
Fire protection technology built for tunnels
Aestuver® fire protection boards combine tested structural fire protection with outstanding weather resistance – and meet high standards of safety, cost-effectiveness and durability.
Their product properties make them a reliable choice for the most demanding applications in structural fire protection, tunnel construction and industry.
Thanks to their matrix structure, Aestuver® fire protection boards are weather-, water- and frost-resistant and classified Type X (including Z1, Z2 and Y) under EAD 350142-00-1106. They are suitable for indoor use and for areas fully or partially exposed to the weather.
Aestuver® fire protection boards are designed for high-quality structural fire protection. They are Class A1 (non-combustible) to EN 13501-1 and suitable for both indoor and exposed outdoor applications.
Aestuver® boards are made from cement-bonded, glass-fibre-reinforced lightweight concrete. This matrix gives them high flexural and compressive strength and a long service life. They can be cut and fixed quickly with standard tools and remain stable even in high humidity.
Technical data: Aestuver® fire protection board
Documents and technical data
Technical data, specifications and documents for the Aestuver® fire protection board – ready for design, tendering and installation.
Data for further board types is available in the download centre.
Apparent density (dry)
~ 625 – 965 kg/m³
Thermal conductivity
approx. 0.21 W/(m·K) (20 mm board, DIN 12667)
Specific heat capacity c
~ 0.9 kJ/kg·K
Expansion/shrinkage (Δ RH 30 %, 20 °C, EN 318)
± 0.1%
Equilibrium moisture content (65 % RH, 20 °C, DIN EN ISO 12570)
~ 7% by weight
Alkalinity (pH value)
~ 12
Application category – intended use (EAD 350142-00-1106)
Type 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
Application category – climatic conditions (EAD 350142-00-1106)
Type X (incl. Z1, Z2, Y)
Thickness in mm
10, 12, 15, 20, 25, 30, 40, 50, 60 mm
Dimensions (L x W)
2600 x 1250 mm / other dimensions available on request
Building material class (in accordance with DIN EN 13501-1)
non-combustible, A1
Full technical data is available in the product data sheet.
Project references
Project support from our tunnel experts
Which fire protection board is right for your tunnel?
The right board depends on the tunnel type, construction method, design fire curve and installation conditions. Our specialists will help you choose the right solution for your project.
Coatings with commercially available dispersion-, silicate-, synthetic resin- or acrylic-based products are possible. A deep-penetrating primer is recommended. For skimming the surface, fermacell™ Powerpanel fine surface treatment is suitable in combination with full-surface reinforcement using fermacell™ HD reinforcing mesh. The fermacell™ HD render system is also approved. Application instructions can be found from page 103 of the Aestuver® manual.
According to the European Assessment Documents (EADs), there are four use categories:
Type X: indoors, partially exposed and fully exposed to the weather – the highest requirement level
Type Y: indoors and areas partially exposed to the weather (e.g. covered outdoor areas)
Type Z1: indoors with high humidity or fluctuating temperatures
Type Z2: indoors only, with constant climatic conditions
Aestuver® fire protection boards meet the highest category, Type X (EAD 350142-00-1106).
Aestuver® fire protection boards are available from building materials retailers in Germany, such as specialist dealers for drywall, insulation, roofing and insulation technology.
Depending on the construction, the boards are either fixed board-to-board with staples or screws, or mounted on a metal, timber or concrete substructure. Detailed recommendations on suitable fixings can be found on pages 106–107 of the Aestuver® manual.
Technically, Aestuver® fire protection boards can be used outdoors permanently without an additional coating. For aesthetic reasons, however, we recommend structural weather protection or a suitable coating. Exception: in road tunnels, a surface coating is required for frost and road-salt resistance. Detailed information can be found from page 103 of the Aestuver® fire protection manual.
More Aestuver® products
Aestuver® fire protection boards are used far beyond tunnels – from structural fire protection in buildings to demanding infrastructure projects and specialist applications.