The right solution for your tunnel project
Fire protection requirements depend on the tunnel structure and the area of use. Explore our solutions for different tunnel types and for the safety-critical areas of tunnel infrastructure.
Solutions for tunnel fire protection
The right solution starts with the requirements
Tunnel type, construction method, fire exposure and installation conditions all shape the design of the fire protection system. Alongside choosing the right product, design fire curves, structural requirements and protection of the concrete play a key role.
Aestuver® tunnel brochure
From tunnel linings and movement joints to fixing solutions: in our tunnel brochure, you will find comprehensive information on requirements, system solutions and areas of application in passive fire protection for tunnel structures.
Tunnel Support: expert help for your project
From choosing the right fire protection system and technical design to fire curves, tenders and project-specific requirements: our experts support you throughout the planning of your fire protection solution.
Which fire protection solution is right for your tunnel?
Our experts will help you find a suitable solution to meet the requirements of your tunnel project.
FAQ
Answers to the most common questions about concrete spalling, tunnel fire protection and the applications of Aestuver® fire protection boards.
Passive fire protection acts as a thermal barrier between the fire and the concrete structure. This reduces the critical temperatures reached by the concrete and reinforcement, thereby significantly reducing the risk of concrete spalling. |
Yes. Studies show that fire protection panels can significantly reduce repair times and tunnel closures. This helps to reduce the high costs associated with diversions, traffic disruption and loss of use. |
Existing tunnels can be protected by retrofitting fire protection cladding. The fire protection panels are mechanically fixed to walls and ceilings, protecting the existing concrete structure from damaging temperatures in the event of a fire. |
Yes. The surface is abrasion-resistant and can be cleaned using high-pressure washers, tunnel wash systems or industrial brushes. Its cleanability has been tested in accordance with DIN EN ISO 11998. |
Individual slabs can be removed for inspections or repairs and then reinstalled. This ensures that leaks or damage to the concrete structure remain easily accessible. |
More Aestuver® products
Aestuver® fire protection boards are used far beyond tunnels – from structural fire protection in buildings to demanding infrastructure projects and specialist applications.