Preventing concrete spalling in tunnel fires

Tunnel design fire curves such as the EBA curve assume temperatures of 1,200 °C within just five minutes. The result can be explosive concrete spalling, exposed reinforcement and high repair costs. Passive structural fire protection with Aestuver® fire protection boards reduces these risks.

What is concrete spalling?

When concrete fails under heat

Tunnel fires cause extreme temperatures and high thermal stresses. When concrete heats up rapidly from the surface, the moisture inside it evaporates and builds up steam pressure. This can cause explosive spalling: layers of concrete break away from the surface and expose the reinforcement.

High-strength and high-performance concretes are particularly prone to spalling, because their reduced pore volume lowers permeability and makes it harder for the steam pressure to escape.

Concrete spalling mechanisms
Why does concrete spall?

The mechanism behind structural spalling
Spalling is not caused by the fire alone. The decisive factor is the interplay of temperature, moisture and pressure within the structural element.

Exposure to extreme heat

The EBA design fire curve assumes 1,200 °C in the tunnel after just five minutes. The concrete surface heats up extremely quickly.

Steam pressure in the concrete

Moisture in the concrete evaporates. In dense, high-performance concrete in particular, the steam cannot escape quickly enough.

Thermal stresses

Large temperature differences between the surface and the core create high internal stresses in the component.

Explosive spalling

Layers of concrete suddenly break away from the surface. The reinforcement is exposed and the tunnel structure can be damaged.

What are the consequences of spalling for the tunnel?

The consequences go far beyond the fire damage

01
Loss of load-bearing capacity

Spalling can compromise the integrity of the tunnel structure and reduce the load-bearing capacity of critical structural elements.

02
Exposed reinforcement

Once the concrete cover spalls, the reinforcement is left unprotected – exposed to high temperatures and, through hairline cracks, to carbonation and chlorides that can corrode the steel.

03
High refurbishment costs

Repairing fire-damaged concrete is complex and leads to substantial repair and restoration costs.

04
Long closure periods

Severe fire damage can close a tunnel for long periods – with a significant impact on traffic, tunnel operators and the surrounding region.

How can concrete spalling be prevented?

Concrete spalling is best prevented at the planning stage rather than repaired after a fire. Passive fire protection systems such as Aestuver® fire protection boards act as a barrier that keeps heat away from the concrete, significantly reducing the risk of structural damage.

Protection of the structure

Aestuver® fire protection boards protect tunnel structures from extreme temperatures and prevent spalling and damage that could jeopardise structural stability.

Reducing cost risks

Less damage to the structure means less restoration work and lower repair costs after a fire.

Rapid return to service

Reliable protection limits consequential damage, so tunnels can be repaired and reopened to traffic sooner.

Long-term safety

The load-bearing capacity and integrity of the structure are maintained – supporting the long-term safety and availability of the infrastructure.

The solution: Aestuver® fire protection boards

Protection for tunnel structures in extreme conditions

Aestuver® fire protection boards reliably protect tunnel structures against extreme thermal loads and help to preserve the structure in a fire. Their technical properties make them suitable both for the highest fire protection requirements and for individual design concepts in modern tunnels.

Learn more about Aestuver® fire protection boards

Benefits of Aestuver® fire protection boards

Non-combustible, heat-resistant, water- and frost-resistant: Aestuver® fire protection boards reliably protect tunnel structures from the consequences of a fire.

Non-combustible
Class A1 to EN 13501-1

The boards add no fire load and release no combustible components in a fire – meeting the strictest structural fire protection requirements for tunnels.

up to 1,400 °C
Heat-resistant

Fire protection up to 1,350 °C (board T) or 1,400 °C (board Tx), tested to international tunnel fire curves.

Weather-resistant
Type X to EAD 350142-00-1106

Resistant to water and freeze–thaw cycles, Aestuver® boards provide durable fire protection in areas fully or partially exposed to the weather.

Durable
Cleanability verified to DIN EN ISO 11998

Abrasion- and moisture-resistant with no organic components, so there is no risk of mould. The boards can be cleaned with high-pressure water jets or tunnel-cleaning vehicles.

Flexible to install. Reliable in a fire.

In new builds and in the refurbishment of existing tunnels, Aestuver® fire protection boards adapt to different construction methods and project requirements. Depending on the application, they can be cast directly into the concrete or post-fixed at a later stage. The result is a cost-effective fire protection solution that integrates flexibly into the construction process and protects the tunnel structure against critical temperatures over the long term.

Post-fixed fire protection cladding

Fire protection cladding cast into concrete (permanent formwork)

White paper: Concrete spalling during tunnel fires

Concrete spalling in tunnel fires can significantly reduce the load-bearing capacity of the tunnel structure. Find out how spalling occurs and how the right fire protection measures keep high temperatures away from the concrete.

Talk to our tunnel experts

Have a specific requirement? Our tunnel fire protection specialists will work with you to develop the right solution – from planning support and project-specific fire tests to technical assistance on site.

FAQ

Answers to the most common questions about concrete spalling, tunnel fire protection and the applications of Aestuver® fire protection boards.

View all FAQs