Thanks to the special performance of Aestuver® fire protection boards, constructions are available for all interior and exterior application categories that offer planners, fabricators, builders and subsequent occupants or users of the buildings the required level of safety.


 

WALLS

Assembly walls

Non-load bearing, room-enclosing partition wall construction in metal stud design. Double-layer planking on both sides for fire resistance F90 or F120. Various design and connection details.

 



Advantages:

  • Fire protection: very slim efficient construction
  • Planning: room-high panels, very smooth surface similar to concrete
  • Moisture: can be used outdoors without additional coating


Building material

  • Building material class (EN 13501-1) A1
  • Material (European regulated) ETA-11/0458

 


Shaft Walls

Non-load bearing room-enclosing partition wall constructions. Can be constructed with metal substructure and without substructure. Planked on one side for single-sided installation with F90 fire resistance.

Advantages

  • Unlimited width, wall height up to 4000 mm 
  • Can be used outdoors without additional coating
  • Installation of access panels possible
  • Room-high panels, very smooth surface similar to concrete
  • Fire protection P-3179/069/14
  • Insulation material not required

 

Building material

  • Building material class (EN 13501-1) A1
  • Material (European regulated) ETA-11/0458
 

Steel frame walls

Non-load bearing, space-enclosing partition wall construction in metal stud construction, with extended wall heights. Single-layer cladding on both sides for fire resistance F90 or F120. Various design and connection details.

 

Advantages

  • Load-bearing and non-load-bearing
  • Can be used for high rooms (wall heights up to 5.49 m)
  • High stability, mechanically loadable
  • Can be used outdoors without additional coating
  • Fire protection P-3249/1399: F 120-A
  • Insulation material not required

Building material
  • Building material class (EN 13501-1) A1
  • Material (European regulated) ETA-11/0458

  


CEILINGS

Suspended ceilings

Suspended, self-supporting substructures, with single or multi-layer coverings. For various types of bare ceilings with fire resistances F60 - F90.
 

Advantages

  • Fire protection P-3243/1339: F 60-A - Type II, III
  • Fire protection: no insulation material required
  • Planning: large spans by varying the thickness of the planking
  • Application: can be used outdoors without additional coating & lightweight individual components


Building material

  • Building material class (EN 13501-1) A1
  • Material (European regulated) ETA-11/0458
 

 

Trapezoidal steel sheet ceilings

 

Cladding for statically freely shape trapezoidal steel sheet ceilings with fire resistances up to F120.

Advantages

  • Fire protection P-SAC-02/III-723: F60-A from below
  • Insulation material 60 mm / 150 kg/m³
  • Can be used outdoors without additional coating
  • Lightweight individual components
  • Can be mounted from below


Building material

  • Building material class (EN 13501-1) A1
  • Material (European regulated) ETA-11/0458

.


 

Trapezoidal steel ceiling F90

Advantages

  • Fire protection P-SAC-02/III-723: F90-A from below
  • Insulation material 60 mm / 150 kg/m³
  • Can be used outdoors without additional coating
  • Lightweight individual components
  • Can be mounted from below


Building material

  • Building material class (EN 13501-1) A1
  • Material (European regulated) ETA-11/0458
 

 
If you want to learn more about why you should choose Aestuver fire protection panels please check this article
×