James Hardie® offers holistic solutions for preventive structural fire protection. That is why fire protection products in form of systems are also part of the range.
In the event of a fire, cable systems can be damaged, resulting not only in dense smoke damage but also in highly toxic gases. Within a few minutes, escape and rescue routes can become a deadly trap. In addition, the work of the emergency services is made more difficult or even impossible.

Aestuver® offers the following solutions to ensure that manufacturers of components and systems also meet the high fire protection requirements in this case:

 
Aestuver Installation channel

Installation channels (I channels)

Aestuver® Installation channels prevent the transmission of fire from the inside to the outside and protect the surrounding rooms, e.g. escape and rescue routes (fire load clearance). A spillover on e.g. ceiling cavities is prevented. These cable ducts are tested according to DIN 4102-11.
 


 

Fire protection cable ducts for function maintenance (E ducts)

Aestuver® Fire protection cable ducts for function maintenance ensure that in the event of a fire, no fire penetrates into the duct from outside and that the temperatures inside remain low. This ensures that no short circuit occurs or that the power supply is interrupted. These cable ducts are tested according to DIN 4102-12.
 

Fire protection cable ducts for function maintenance

 

Fire protection ducts for encapsulating the fire load (I-ducts).

Aestuver® installation channels prevent fire from spreading from the inside to the outside and protect surrounding rooms such as escape and rescue routes (fire load containment). A spread to e.g. ceiling cavities is prevented. These cable ducts are tested according to DIN 4102-11.
 

Constructions for installation ducts 

Duct system     Panel thickness [mm] Duct dimension
(inside) [mm]    
Duct length
[mm]    
Slopes
distance [mm] 
Duct weight [mm]  Fire protection
5 KI 31 AE Aestuver Standard L90

Aestuver_Kanal_Standard
Cover: 20 + 10 
Bottom: 15 mm
Wall: 30 mm
Collar: 10 mm
max. 170  x 95  max. 1 250  - appx. 10,0 kg/m acc. to DIN 4102-11: L90
P-3109/0998
GA: GS 3.2/15-015-1
5 KI 12 AE Aestuver Exclusiv L30

Aestuver_Kanal_exclusiv
Coverl: 25 mm
Bottom: 25mm
Wall: 25 mm
Collar: 25 mm
max. 750  x 450  max. 1 250  max. 1 250 appx. 37,5 kg/m acc. to DIN 4102-11: L 30
P-3245/1359
GA: GS 3.2/15-016-2
5 KI 32 AE Aestuver Exclusiv L90

Aestuver_Kanal_exclusiv
Cover: 40 mm
Bottom: 40mm
Wall: 40 mm
Collar: 40 mm
max. 780  x 480  max. 1 250  max. 1 250 appx. 68,5 kg/m acc. to DIN 4102-11: L 90
P-3245/1359
GA: GS 3.2/15-016-2

Fire protection cable trunking for function maintenance (E-trunking)

Aestuver® fire protection cable ducts for function maintenance ensure that in the event of a fire, no fire penetrates the duct from the outside and the temperatures inside remain low. This ensures that no short circuit occurs or the power supply is interrupted. These cable ducts are tested according to DIN 4102-12.
 

Constructions for electrical ducts

Duct system     Panel thickness [mm] Duct dimension
(inside) [mm]    
Duct length
[mm]    
Slopes
distance [mm] 
Duct weight [mm]  Fire protection
5 KE 11 AE Aestuver Standard E30

Aestuver_Kanal_Standard
Cover: 20 + 10 mm
Bottom: 15 mm
Wall: 30 mm
max. 170  x 95  1 000 mm - appx. 10,0 kg/m acc. to DIN 4102-12: E 30
P-330/381/14
GA: GS 3.2/15-017-1
5 KI 32 AE Aestuver Exclusiv L90

Aestuver_Kanal_exclusiv
25 x 25 x 25 
20 x 20  x 20 
25 x 25  x 25 
20  x 20 x 20 
max. 150 x 150 
max. 740 x 440 
max. 875 x 500 
max. 845 x 500 
max. 1 250  1 250 mm
   900 mm
1 250 mm
   900 mm
appx. 13,5 kg/m
appx. 10,0 kg/m
appx. 51,0 kg/m
appx. 43,5 kg/m
acc. to DIN 4102-12: E 30
P-3246/1369
GA: GS 3.2/15-018-2
5 KI 32 AE Aestuver Exclusiv L90

Aestuver_Kanal_exclusiv
60 x 60 x 60
50 x 50 x 50
60 x 60 x 60
max. 220 x 220 
max. 200 x 200 
max. 875 x 500
max. 1 250  1 250 mm
   900 mm
1 250 mm
appx. 24,5 kg/m
appx. 19,5 kg/m
appx. 99,0 kg/m
acc. to DIN 4102-12: E 90
P-3246/1369
GA: GS 3.2/15-018-2

Intelligent fire protection with Aestuver®

  • Powerful systems
  • Economic solutions
  • Preventive fire protection
  • High-quality fire protection panels

Aestuver™ Combination bulkheads

Bulkhead system Application area Component thickness Bulkhead size Bulkhead thickness Fire protection
5 A 31 ABL Aestuver™ Combination bulkhead ABL

Kombischott_ABL
Solid walls
Solid ceilings
non-load-bearing 
Assembly walls

Wooden panel construction (wall)
Wooden panel construction (ceiling)
> 100 mm
> 150 mm
> 100 mm


> 100 mm
> 150 mm
< 1 000 x 1800 (H)
< 1 000 x unlimited (L)
< 1 000 x 1800 (H)


< 1 000 x 1800 (H)
< 1 000 x unlimited (L)
> 120 mm acc. to DIN 4102
resp. DIN EN 13501-2: S90

Z-19.15-1870


The AESTUVER™ ABL combination bulkhead enables single or joint penetration of electrical cables as well as combustible and non-combustible pipes through solid ceilings, solid walls and lightweight partition walls. As a penetration seal of fire resistance class S 90 according to DIN 4102, Part 9, it prevents the transmission of fire and smoke for a duration of 90 minutes.

System components:

  • AESTUVER mineral wool board ABL (article number: 8041005)
  • AESTUVER Coating ABL (article number: 8041006)
  • AESTUVER filler ABL (article number: 8041007, 12.5 kg / article number: 8041008, 310 ml)
  • Identification plate AESTUVER Kombischott ABL (Article number: 8041009
5 A 31 S Aestuver™ Combination bulkhead S

Kombischott_S_Anwendung
Kombischott_S_Anwendung
Solid walls
Solid ceilings
non-load-bearing 
Assembly walls





Wooden panel construction (wall)
Wooden panel construction (ceiling)
> 100 mm
> 150 mm
> 100 mm





> 100 mm
> 150 mm
< 1 000 x 1800 (H)
< 1 000 x unlimited (L)
< 1 000 x 1800 (H)





< 1 000 x 1800 (H)
< 1 000 x unlimited (L)
> 200 mm acc. to DIN 4102
resp.. DIN EN 13501-2:
EI 15
EI 20
EI 30
EI 45
EI 60
EI 90

ETA-11/0206
i.V.m.
GS 3.2/14-192-1
 

The AESTUVER™ ABL combination bulkhead enables single or joint penetration of electrical cables as well as combustible and non-combustible pipes through solid ceilings, solid walls and lightweight partition walls. As a penetration seal of fire resistance class S 90 according to DIN 4102, Part 9, it prevents the transmission of fire and smoke for a duration of 90 minutes.

System components:

  • AESTUVER mineral wool board ABL (article number: 8041005)
  • AESTUVER Coating ABL (article number: 8041006)
  • AESTUVER filler ABL (article number: 8041007, 12.5 kg / article number: 8041008, 310 ml)
  • Identification plate AESTUVER Kombischott ABL (Article number: 8041009
 
5 A 31 ST Aestuver™ Combination bulkhead ST

Aestuver_Kanal_exclusiv
Aestuver_Kanal_exclusiv
Solid walls
Solid ceilings
non-load-bearing 
Assembly walls





Wooden panel construction (wall)
Wooden panel construction (ceiling)
> 100 mm
> 150 mm
> 100 mm





> 100 mm
> 150 mm
< 1 000 x 1000 (H)
< 700 x unlimited (L)
< 840 x 570 (H)





< 1 000 x 1000 (H)
< 400 x unlimited (L)
> 200 mm acc. to DIN 4102
resp. DIN EN 13501-2: S90

Z-19.15-1182
i.V.m.
GS 3.2/14-192-1
 

The AESTUVER combi bulkhead ST seals off electrical cables and conduits without fibres and in a fire-protection-safe manner. Subsequent changes to the layout are possible without any problems.

System components:

  • AESTUVER fire protection brick 200 ST (article number: 8041010)
  • AESTUVER fire protection block 200 ST-v (article number: 8041011)
  • AESTUVER fire protection compound ST (article number: 8042006)
  • Identification plate AESTUVER cable penetration seal/combination penetration seal (article number: 8041009)

Aestuver® offers its partners and customers individual advice - fair, needs-based and personal. In addition to custom-fit products, we offer comprehensive services - free of charge, of course.