2 S 21 AE Aestuver ceiling construction (type II, III)

Component:

  • Fire protection P-3243/1339: F 60-A - Type II, III
  • Insulation material not required
  • Planking ≥ 10 mm
  • Component weight ≥ 14 kg/m²
  • Construction height ≥ 70 mm


Building material

  • Building material class (EN 13501-1) A1
  • Material (European regulated) ETA-11/0458


Advantages

  • Fire protection: no insulation material required
  • Planning: large spans by varying the thickness of the planking
  • Application: can be used outdoors without additional coating & lightweight individual components
×